Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
01 25 2017 Council Agenda
The Township of Oro-Medonte Council Meeting Agenda Council Chambers Wednesday, January 25, 2017 9:00 a.m. - Closed Session 10:00 a.m. - Open Session Page 1. Call to Order - Moment of Reflection: 2. Adoption of Agenda: a) Motion to Adopt the Agenda. 3. Disclosure of Pecuniary Interest: 4. Closed Session Items: a) Motion to go In Closed Session. b) Motion to Rise and Report. c) Robin Dunn, CAO re: Solicitor-client privilege (Legal File Update) \[To Be Withdrawn\]. d) Robin Dunn, CAO re: Litigation affecting the municipality (Burl's Creek). e) Robin Dunn, CAO re: Labour relations/employee negotiations (Staffing) \[To Be Withdrawn\]. 5. Minutes of Council and Committees: 6 - 7a) Minutes of Special Council meeting held on Wednesday, January 4, 2017. 8 - 12b) Minutes of Special Council meeting held on Monday, January 9, 2017. 13 - 27 c) Minutes of Council meeting held on Wednesday, January 11, 2017. 28 - 30 d) Minutes of Special Council meeting held on Friday, January 13, 2017. 31 - 43 e) Minutes of Heritage Committee meeting held on Monday, January 16, 2017. 6. Recognition of Achievements: None. 7. Public Meetings: None. Page 1 of 260 Council Meeting Agenda - January 25, 2017 8. Deputations: None. 9. Presentations: None. 10. Identification From the Public of an Agenda Item of Interest: Provides an opportunity for members of the public to identify an agenda item which the public member may request be brought forward and considered earlier in the meeting. 11. Open Forum: The Open Forum provides an opportunity for the public to provide verbal comments to Council, in Open Session, on matters scheduled on the current agenda, and shall be conducted as follows: Open Forum shall last no longer than 20 minutes; Each speaker shall be required to identify the agenda item they are speaking to and provide their name and address, which may become part of the public record; A speaker shall be limited to 2 minutes per agenda item; No response shall be provided to any question posed during Open Forum; No discussion, debate or decisions will occur during Open Forum; Each speaker is permitted to speak only once per agenda item; A speaker may provide comment on one agenda item and then shall step aside to enable another to provide comment on an agenda item; No speaker shall speak to a second agenda item until other individuals have had an opportunity to speak once; Speakers providing comment on the same agenda item, shall be requested to limit their comments so as to provide additional information and not repeat the same information provided by a previous speaker; Comments made during Open Forum will not form part of the minutes of the meeting; The following matters will not be permitted during Open Forum: o Comments/complaints against Members of Council or Township staff; o Matters beyond the jurisdiction of Council or the Township; o Closed Session agenda items, including current or pending litigation, or Insurance claims and/or pending claims by or against the Township; o Comments with respect to Minutes of Council and Committees; o Comments that are contrary to the Municipal Freedom of Information and Protection of Privacy Act; Page 2 of 260 Council Meeting Agenda - January 25, 2017 o Comments with respect to any applications which have proceeded through a Public Meeting in accordance with the Planning Act, with the exception of comment related to a recommendation contained within the Staff Report. The Chair may conclude Open Forum prior to the 20 minute maximum time limit, for non-compliance with the Open Forum parameters, Conduct of Members of the Public, or any other reason. 12. Reports of Municipal Officers: 44 - 50 a) Report No. FI2017-02, Paul Gravelle, Director, Finance/Treasurer/Deputy CAO re: Statement of Investment Activities. 51 - 53 b) Report No. FI2017-03, Paul Gravelle, Director, Finance/Treasurer/Deputy CAO re: Report on Tax Arrears. 54 - 125 c) Report No. OCS2017-01, Shawn Binns, Director, Operations & Community Services re: Township Community Hall Building Condition Audits. 126 - 229 d) Robin Dunn, CAO and Senior Management Team re: 2017 Budget Presentations and Deliberations. 13. Reports of Members of Council: a) Updates from Council Representatives County of Simcoe and Township Partners and Agencies. on the activities of the County of Simcoe Agencies. 230 - 231 b) Mayor H.S. Hughes, correspondence dated January 10, 2017 from Elizabeth Slomke, Clerk, Town of Fort Frances re: Resolution to Address the Inequity in Property Taxation on Railway Right-of-Way's Collected by Municipalities in Ontario. 232 - 233 c) Mayor H.S. Hughes, correspondence dated December 13, 2016 from Janet Nyhof, Deputy Clerk, City of Orillia re: Sustainable Funding Support for Child Advocacy Centres and the Child Advocacy Centre Simcoe/Muskoka. 14. Consent Agenda: 234 - 236 a) Announcements of Interest to the Public: 1. Orillia & Area Physician Recruitment & Retention Committee, Winter Wonderland, Friday, February 24, 2017, The Orillia Public Library, 7:00p.m.-11:00p.m. 2. Township of Oro-Medonte, 2017 Oro-Medonte Citizen of the Year and Ontario Senior of the Year Nomination Notice. 3. Ontario Energy Board Public Hearing Notice, Enbridge Gas Page 3 of 260 Council Meeting Agenda - January 25, 2017 Distribution Inc. has applied to Renew its Natural Gas Franchise Agreement for the Township of Oro-Medonte, Active Participation Deadline due by January 30, 2017. 237 - 239 b) Correspondence received January 17, 2017 from Chris Ballard, Minister, Ministry of Housing re: The Promoting Affordable Housing Act, 2016. Staff Recommendation: Receive. 15. Communications/Petitions: 240 a) Correspondence from Association of Municipalities of Ontario (AMO) re: AMO Annual General Meeting and Annual Conference, August 13-16, 2017, Ottawa. 241 - 242 b) Correspondence dated January 9, 2017 from Gayle Wood, CAO, Nottawasaga Valley Conservation Authority (NVCA) re: NVCA 2017 Municipal Levy. 16. Notice of Motions: None. 17. By-Laws: 243 a) By-Law No. 2017-011: A By-law to Amend By-law 2016-- 244 - 259 b) By-Law No. 2017-013: A By-law to Appoint a Meeting Investigator and Repeal By-Law No. 2016-013. 18. Closed Session Items (Unfinished Items): 19. Confirmation By-Law: 260 a) By-Law No. 2017-010: Being a by-law to confirm the proceedings of the Council meeting held on Wednesday, January 25, 2017. 20. Questions from the Public Clarifying an Agenda Item: Questions from the Public Clarifying an Agenda Item provides an opportunity for the members of the public to seek clarification with respect to the decision which was made on an agenda item, the meaning of the decision and the next steps as a result of the decision. Questions from the Public Clarifying an Agenda Item shall last no longer than 10 minutes; Responses provided to questions posed during Questions from the Public Clarifying an Agenda Item shall be included within the 10 minute maximum time limit; Each speaker shall be required to identify the agenda item they are seeking clarification on and provide their name and address, which Page 4 of 260 Council Meeting Agenda - January 25, 2017 may become part of the public record; A speaker shall be limited to 1 minute per question; A speaker may pose a question and then shall step aside to enable another to pose a question; The Chair may conclude Questions from the Public Clarifying an Agenda Item prior to the 10 minute maximum time limit, for non- compliance with the above parameters, Conduct of Members of the Public, or any other reason. 21. Adjournment: a) Motion to Adjourn. Page 5 of 260 5.a) Minutes of Special Council meeting held on Wednesday, J... Page 6 of 260 5.a) Minutes of Special Council meeting held on Wednesday, J... Page 7 of 260 5.b) Minutes of Special Council meeting held on Monday, Janu... Page 8 of 260 5.b) Minutes of Special Council meeting held on Monday, Janu... Page 9 of 260 5.b) Minutes of Special Council meeting held on Monday, Janu... Page 10 of 260 5.b) Minutes of Special Council meeting held on Monday, Janu... Page 11 of 260 5.b) Minutes of Special Council meeting held on Monday, Janu... Page 12 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 13 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 14 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 15 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 16 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 17 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 18 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 19 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 20 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 21 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 22 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Saving the Girl Next Door Act, 2016 Page 23 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 24 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Saving the Girl Next Door Act, 2016 Page 25 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 26 of 260 5.c) Minutes of Council meeting held on Wednesday, January 1... Page 27 of 260 5.d) Minutes of Special Council meeting held on Friday, Janu... Page 28 of 260 5.d) Minutes of Special Council meeting held on Friday, Janu... Page 29 of 260 5.d) Minutes of Special Council meeting held on Friday, Janu... Page 30 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 31 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 32 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 33 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 34 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 35 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 36 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 37 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 38 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 39 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 40 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 41 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 42 of 260 5.e) Minutes of Heritage Committee meeting held on Monday, J... Page 43 of 260 12.a) Report No. FI2017-02, Paul Gravelle, Director, Finance... Page 44 of 260 12.a) Report No. FI2017-02, Paul Gravelle, Director, Finance... Page 45 of 260 12.a) Report No. FI2017-02, Paul Gravelle, Director, Finance... Page 46 of 260 12.a) Report No. FI2017-02, Paul Gravelle, Director, Finance... Page 47 of 260 12.a) Report No. FI2017-02, Paul Gravelle, Director, Finance... Page 48 of 260 12.a) Report No. FI2017-02, Paul Gravelle, Director, Finance... Page 49 of 260 12.a) Report No. FI2017-02, Paul Gravelle, Director, Finance... Page 50 of 260 12.b) Report No. FI2017-03, Paul Gravelle, Director, Finance... Page 51 of 260 12.b) Report No. FI2017-03, Paul Gravelle, Director, Finance... Page 52 of 260 12.b) Report No. FI2017-03, Paul Gravelle, Director, Finance... Page 53 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Page 54 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Page 55 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Page 56 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 PROJECTNo:160200 TOWNSHIPOFOROMEDONTE BUILDINGCONDITION ASSESSMENTS OROMEDONTE,ONTARIO PREPAREDBY: 126MISSISSAGASTREETEAST,ORILLIA,ON,L3V1V7 PH.7053255400FX.7053258400 WWW.STEENHOFBUILDING.COM 2 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 57 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 TABLE OF CONTENTS Letter of Transmittal . .. ... .i Executive Summary .. ... .1-3 Appendix A - Carley Community Hall . ... .. ... . A1-A7 Appendix B Eady Community Hall . . . B1-B11 Appendix C Edgar Community Hall . . .. .. C1-C9 Appendix D Hawkestone Community Hall .. .. D1-D12 Appendix E Jarratt Community Hall .. ..E1-E12 2 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 58 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 Date:October 25, 2016 File:160200 Township of Oro-Medonte, 148 Line 7 South Oro-Medonte, ON L0L 2E0 Attention:Mr. Shawn Binns, Director, and Community Services Dear Mr. Binns, Re:Building Condition Assessments of 5 Buildings for the Township of Oro-Medonte Steenhof Building Services Group (SBSG) is pleased to provide the attached Building Condition Study and Assessments of 5 municipal buildings located in the Township of Oro-Medonte. The buildings are identified as follows: 1.Carley Community Hall 2.Eady Community Hall 3.Edgar Community Hall 4.Hawkestone Community Hall 5.Jarratt Community Hall Our proposed methodology addresses the Scope of Work indicated in our proposal dated May 19th, 2016. The purpose of this report is to document the identified contraventions and to appoint corrective measures for each with a Class D cost estimate associated to the work. This study has been prepared for the exclusive use of the Township of Oro-Medonte Administration and Council. Should a meeting with yourself and other project team members be necessary to review the attached information SBSG would be available to be scheduled at your convenience. We appreciated the opportunity to be of service to you. Should you have any questions resulting from your review of our reports, please feel free to contact myself directly. Sincerely, Jerry Slavish, MAATO Jack Steenhof, P.Eng. Project Manager President STEENHOFBuildingServicesGroupSTEENHOFBuildingServicesGroup -i - 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 59 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 EXECUTIVESUMMARY : 1.Carley Community Hall 2.Eady Community Hall 3.Edgar Community Hall 4.Hawkestone Community Hall 5.Jarratt Community Hall . Carley Community Hall The Carley Community Hall located at 396 Warminster Sideroad is reported to be in general good condition. Several deficiencies requiring immediate repair or replacement are noted in the report. The priority items needing immediate attention are the various areas around the roof showing rust and loose fasteners, as well as the requirement to have a universal washroom within the facility. Eady Community Hall The Eady Community Hall located at 73 Eady Station Road is noted to be in general good condition. Several deficiencies requiring immediate repair or replacement are noted in the report. The priority items needing immediateattentionarethenon-compliantfireseparationsbetweentheupperhall,lowerhalland entrancevestibule, replacement of the guard rail inside of the south side stairs, installment of 5/8 Type X drywall to the basement clad columns, and needed construction of a new wheelchair ramp to the facility. -1 - 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 60 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 Edgar Community Hall The Edgar Community Hall is located at 1167 Old Barrie Road West. The facility is in relatively good condition. Several deficiencies requiring immediate repair or replacement are noted in the report. The priority items needing immediate attention are the non-compliant lobby entrance and basement access including exit devices required on the front door, the 5/8fire rated drywall and fire doors required between the front entrance lobby and the basement or main hall rooms, the extension of the interior railings, and the requirement to redesign the washroom to be compliant with the Ontario Building Code. Hawkestone Community Hall The Hawkestone Community Hall located at 3 Allen Street has been noted to be in good condition. Most deficiencies noted throughout the report are relatively minor in nature. However, there are some priority items needing immediate attention, such as, replacement of the broken bird screen over the exhaust from the washroom, replacement of the fire rated ceiling, and the requirement to redesign and renovate the universal washroom to conform to the Ontario Building Code. Jarratt Community Hall The Jarratt Community Hall is located at 837 Horseshoe Valley Road, and has been noted to be in poor condition. There are noted life safety deficiencies which are recommended to be repaired within the next year to prevent a threat to the building occupants. These repairs specifically include fire rating the basement support columns, replacement of the roof, the requirement to redesign and renovate the washrooms to create a universal washroom, adjust the universal access ramp to eliminate any stop, and the installment of a door actuator or pads to the door at the top of the ramp. Conclusion of Findings The Township of Oro-Medonte takes great pride in the various buildings it maintains in its community and there is evidence of this dedication as shown in the current condition of these buildings. The buildings are generally in good condition and require various levels of remediation, repair and/or replacement of items and systems to be fully functional for the building purpose. The visual inspections were completed to form a base line of the buildings state at the current time and to identify any major deficiencies that require immediate concern and funding. It is important to note that many of the buildings have not been upgraded to conformance with section 3.8 of the Ontario Building Code providing Barrier-Free Accessibility to all required levels and spaces within the building. The buildings with deficiencies relating to barrier-free accessibility items have been discussed in the individual building report and an associated cost for the conversion or upgrades required has been noted in the Table of Deficiencies. It should be noted that the identified buildings where constructed in a period of time where building code and accessibility requirements where non-existent. - 2 - 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 61 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 With the recent Provincial Legislation updates, it is a requirement of all community centers to become accessible. Due to the various applicable standards, such as AODA Accessibility Standards for Customer Service, Ontario Regulation 429/07, and CAN/CSA B651-04 Accessibility of the Built Environment, many municipalities are now required to become a Barrier-Free Municipality. As a result, there is a great focus put on the elements of design that impede those restricted from maneuvering from level to level and in and out of public spaces. The buildings within the Township of Oro-Medontes portfolio will require upgrades and installation of various systems and barrier-free compliant fixtures and finishes to comply with the current and future applicable codes. The appendices of this report is divided into separate sections documenting each facility. Each section will discuss the observations and deficiencies noted on site, as well as provide detailed photo documentation and a cost estimate breakdown for each building. To reference the consolidated estimated cost for repairs the facilities, please refer to table on the following page. STATEMENT OF ESTIMATED COSTS Immediate (0 Yrs) Medium (1-5 Yrs) Low (6-10 Yrs) Facility Total Costs Total Costs Total Costs Carley Community Hall $,0$3,750 $ Eady Community Hall $450$7,100 $0 Edgar Community Hall $41,950$17,000$0 Hawkestone Community Hall $40,150$1,000 $0 Jarratt Community Hall $55,250$4,000 $0 SUBTOTAL $21$32,850$ TOTAL $2 Steenhof Building Services Group submits the following report and Table of Deficiencies (refer to Appendix A)to assist the Township of Oro-Medonte to create a successful Facilities Management Plan. Should you require clarification on any items noted throughout the report, please do not hesitate to contact our office. Sincerely, Jerry Slavish, MAATO Jack Steenhof, P.Eng. Steenhof Building Services Group.Steenhof Building Services Group -3 - 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 62 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 APPENDIX A 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 63 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment . _ Carley Community Hall, Oro-Medonte, ON PROJECT No. 160200 Carley Community Hall Oro-Medonte, Ontario Building Condition Assessment PROJECT No: 160200 126 MISSISSAGA STREET EAST, ORILLIA, ON, L3V 1V7 PH. 705-325-5400 FX. 705-325-8400 WWW.STEENHOFBUILDING.COM 126 MISSISSAGA ST. E, ORILLIA, ON L3V 1V7 WWW.STEENHOFBUILDING.COM P. 705.325.5400 October 25, 2016 Page 64 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Carley Community Hall, Oro-Medonte, ON PROJECT No. 160200 OBSERVATIONS On the afternoon of Thursday, June 30, 2016, Mr. Doug Hackbart, P.Eng. of Steenhof Building Services Group assessed the Carley Community Hall. Site Work A new sidewalk has been installed to the parking lot. The grounds were generally in very good condition with one swampy area where the sump pump emptied out (see image 11). Exterior Walls & Structure There is cracked mortar around the kitchen entrance door frame where it laps onto the frame; mortar should be terminated alongside the frame and be sealed with a sealant bead (see image 1). Recent foundation waterproofing appears to be a blue skin (above grade) membrane, which has not been terminated securely or UV protected. There is also no evidence of protection board over the membrane. It is therefore separating from the wall and will soon allow moisture behind (see image 4). Windows & Exterior Doors The two front window sills have been patched with mortar but are cracked again (see image 2), replacement of mortar is recommended. All windows have been upgraded to vinyl frames with sealed glazing units. Interior Work The plaster in the storage room is heavily cracked, possibly due to evident recent foundation improvements (see image 5). The basement has been recently renovated with a concrete floor, drywall to walls, columns and ceiling. It appears to be have been recently prime-painted, except for the ceiling (see image 6). The basement is being used for storage and is quite orderly at this time (see image 7). Images 17 and 18: interior pictures of main hall (no observations to report at this time). Images 19 and 20: interior pictures of kitchen (no observations to report at this time). The wood floor and subsequent under structure appear to be deteriorating throughout the main room. There is evidence of rotting members below that should be further investigated by pulling up the hardwood floor and core testing the joists to determine depth of damage. This is more evident close to the south wall under the windows. There is no access from below to visually check at this time (see image 21). A1 Page 65 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Carley Community Hall, Oro-Medonte, ON PROJECT No. 160200 Mechanical, & Plumbing The furnace is newer, oil, complete with combustion air supply and HRV system (see images 9 and 10) The well water purification system, hot water tank and sump pump, all appeared to be newer and in good condition (see images 16 and 12) Fire Prevention, Security & Life Safety Systems There are fire extinguishers at both exterior doors and the mechanical room in the basement. The furnace room appears to be properly fire rated although the door was propped open and some latex paint storage was evident (see image 8). Nosings have been added to the basement stairs to increase tread length (see image 15). Stair remains non-compliant due to lack of landing at door. Independent smoke alarms were noted throughout the building, although certain detectors were yellowed and are most likely past useful life. Exit signs are compliant, but lighting units to be checked for operation and replace battery/unit as required. Electrical No observations to report at this time. Roofing Inspections Various areas around the roof, especially at the bottom edges are showing rust and some loose fasteners (see image 3). Barrier-Free Inspections The men_s and women_s washrooms were clean and functional but no universal access features present or room to incorporate without a major renovation (see images 13 and 14). Environmental Assessment No observations to report at this time. Image 1: Cracked mortar at kitchen entrance Image 2: Front windows - mortar cracked again A2 Page 66 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Carley Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 3: Bottom edges of roof: rust & loose Image 4: Foundation waterproofing _ separating fasteners from wall, allowing moisture behind it Image 5: Heavily cracked plaster in storage room Image 6: Recently renovated basement Image 7: Storage in basementImage 8: Furnace room, door propped open & latex paint stored A3 Page 67 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Carley Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 9: Furnace with combustion air supply Image 10: Hot water tank & HRV system Image 11: Grounds _ swampy area near sump Image 12: Hot water tank, sump pump pump Image 13: Men_s washroom Image 14: Women_s washroom A4 Page 68 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Carley Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 15: Nosings added to the basement stairs Image 16: Water purification system Image 17: Main hall Image 18: Main hall Image 19: Kitchen area Image 20: Kitchen area A5 Page 69 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Carley Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 21: Main floor _ deteriorating wood flooring A6 Page 70 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Carley Community Hall, Oro-Medonte, ON PROJECT No. 160200 CARLEY HALL Immediate Medium Low Code Reference Deficiency Suggested Solution (0 Yrs) (1-5 Yrs) (6-10 Yrs) (OBC) Swampy area on grounds, where Add a swale or French drain. $1,5003.1.18.1 (1) the sump pump emptied out (see image 11). Cracked mortar around the kitchen Terminate mortar at edge of door $3009.20.3 entrance door frame where it laps frame and bond or sealant added 9.20.4 onto the frame (see image 1). to make a smooth-tight seal. Blue skin membrane foundation Apply termination bar at grade to $7509.13.3 waterproofing has not been secure membrane and trim 9.13.3.5 terminated securely or UV excess. Expect shortened life of protected. It is separating from the waterproofing, monitor wall (see image 4). accordingly. Two front window sills have been Replace sills. $1,5009.7.6.2 patched with mortar but are cracked again (see image 2). The plaster in the storage room is Cosmetic fix repair cracks and $1,000-Good engineering heavily cracked (see image 5). paint.practice -Maintenance The furnace room appears to be Door should not be propped open. No cost. 3.1.8 properly fire rated although the door 3.1.8.5 was propped open and some latex paint storage was evident (see image 8). Various areas around the roof, Repair roof to increase life. $3,000 - -Good engineering especially at the bottom edges are Improve fasteners and coat rusty $5,000practice showing rust and some loose areas. -Maintenance fasteners (see image 3). The mens and womens washrooms Add ramp, door operators and Ramp - Ramp: 3.8.3.4 did not have any universal access barrier-free washroom. Will only be $2,000Washroom: 3.8.3.12 features present or room to sufficient room to replace current 2 Est. door incorporate without a major washrooms with a unisex barrier-operators - renovation (see images 13 and 14).free washroom, unless renovated $2,500 and reduce kitchen area or add-onBarrier-free to the building. unisex washroom - $20,000 Investigate flooring material and Remove hardwood flooring at Floor and $15,000$45,000 joist deteriorating in main room window areas and core drill joists joist to ascertain depth of rot. remediation Determine repair and restoration $2,500 - after investigation. $45,000 Replace expired Smoke/heat Check and replace outdated $350$350 detectors detectors TOTAL ESTIMATED COSTS:$31,850 $3,750 $,650 A7 Page 71 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 APPENDIX B 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 72 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessment.__.EadyCommunityHall,OroMedonte,ON PROJECTNo.160200 EadyCommunityHall OroMedonte,Ontario BuildingConditionAssessment PROJECTNo:160200 126MISSISSAGASTREETEAST,ORILLIA,ON,L3V1V7 PH.7053255400FX.7053258400 WWW.STEENHOFBUILDING.COM OBSERVATIONS 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 73 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 OntheafternoonofTuesday,June28,2016,Mr.DougHackbart,P.Eng.ofSteenhofBuildingServicesGroupassessed theEadyCommunityHall. SiteWork Sumppumpisexhaustingthroughapieceofdownspoutnexttothebuilding,ponding(seeimage10). Brokentreelimbbehindbuilding(seeimage11).Alsonotethatthetreebranchesareincontactwiththe asphaltroofshinglesattherearofthebuildingandwilldamagetheshingles. ExteriorWalls&Structure Finediagonalcrackanddeterioratedmortarnotedoverfrontentrancedoor(seeimage1). Cracksaboveallsouthsidewindows,someextendingintobrickwork(seeimage2). Southfacebrickworkhasdeterioratedmortarandloosebricksinvariousareas(seeimage4). Exhaustventfrombasementwashroomisbrokenoff(seeimage9). Finecracksaboveallwindowsonthenorthsideandwest(front)aresimilartosouthsidecondition. Brickworkisingoodshapeonnorthside. Windows&ExteriorDoors nd Southside2basementwindowfromwest:deterioratedsillneedsrepair(seeimage3). Doorframeattopoframpismissingvinylcladding(seeimage7). Noted:allwindowstolowerhallhavebeenupgraded. Roofing&InteriorWork Shedroofatsouthsideisdrainingontobrickworkbelowandshouldhavea_kickout_(seeimage5). Therearenoeavestroughsonthemainroof. Eavestroughabovesouthsideprojectionisdamaged(seeimage8). Missingdownspoutsatnortheastcorner&midnorthcorneroftheroof(seeimage14). aroofleakatthesouthwestcornerofthemainhallatsometimeinthe Thereisevidencethattherewas past,butIassumethatthiswasbeforethecurrentsteelroof(seeimage18). Noted:doortostorageareaunderstageisoffitshinges. Mechanical,&Plumbing tobeoperating. Sumppumpisnoted Sewerispumpedtoasepticfield. Furnaceroomisservingasamessystoragearea(seeimage26) Heatingisbyforcedairoilfurnace. HotwaterprovidedbyCascade40&Cascade60waterheaters. WellwaterhasfiltersandUVisnoted. FirePrevention,Security&LifeSafetySystems NonCompliantmainlobby.Nofireseparationsbetweenupperhall,lowerhallandentrancevestibule. o Referencetocode9.2.3.15(1)and3.4.4.1(1)oftheOBC,theexistingdoorsandframesshallbe replacedwith45minuterateddoorsandframeswithapplicablehardwareincludingclosers.The doorsinquestionincludethedoubledoorstothemainroomandthedoorleadingtothe basementlevel.(seeimage13&27). B2 Page 74 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 o Exitsignsarenotpresentinlobby,abovethedoorsleadingfrommainhall,tobeinstalled. o Doorswingsofthedoubledoorstobeinstalledinthedirectionofegress.Thispresentsanissue withtheproximityofthestairsandlanding,posinganissueofinjuringpersonsonthelanding. Redesignofthemainentranceandegressisrecommended. o Thewallsbetweenthemainhallandthelobbyshallbefireratedto1hour.Thewallsappearto benoncompliant.Alayerof5/8_drywallshallbeinstalled,jointssealedandtaped.Removalof thewainscotingwouldberecommendedtofacilitatetheinstallation.Allpenetrationstobefire sealedthroughthe1hourwallbyappropriatemeans. NonCompliantrearexitstairway o Referencetocode3.4.4.1.(1)OBCforexitstairwayseparationrequirements o Rearstairwelldoortobereplacedwith45minuterateddoorandframe,associatedhardware andrepairstoarea. o Stairsrequirearailingtocomply(seeimage17) o Existingrailingaroundsouthstairtobasementisnoncompliant,withpicketspacing>4_,at5_ presently,andonly30_tall(seeimage16) NonCompliantDraperyandwallfinishes o Referencetocodes2.3.2.1.(1),9.2.2.4.(1),3.1.4.5.(3),subsection3.1.11(OBC)andNFPA705to Draperyandfinishesflamespread. o Draperyinmainhalldonotcarryflamespreadrating,shallberemoved/replaced o InteriorwallfinishesconsistofLauanplywoodpaneling,whichisinstalledabovethewoodplank Lauanplywoodisnotlabelledastotheflamespreadratingandis paneling(wainscoting).The assumedtobenoncompliantandshallbecoveredbyfireresistantdrywall.Thewainscoting consistingofwoodplanksarecompliantanddonotrequireanymodification. Noncompliantfireseparationbetweentheatricalspacesandassemblyoccupancies o Codereference3.3.2.14(3to5)OBCreferstofireseparationbetweenstagesandassemblyareas. o Theexistenceofthecurtainacrossthestagesuggeststhattheatricalactivityispresentatthis facility.Thedefinitionof_stage_withintheOBCstatesthatthespacehastobedesignated primarilyfortheatricalperformanceswiththeprovisionsforlighting,changingscenery, environmentalcontrols,controlsforlightingandsound.TheEadyCommunityHalldoesnot exhibittheattributesofatheatricalsettingsaveandexceptforthedividingcurtain. o Itisrecommendedthatthecurtainandsupportberemovedtoalleviatethecoderequirement. Noncompliantsupportpostsinbasementandopeningsindrywallceiling o Nominal4x4postsinbasementlevelshallbecoveredinfireresistancematerial,drywallis recommended(seeimage#24) o Openingindrywallceilingtobefilled,tapedandsealedforlargeopenings o Openingsaroundpiping,ductwork,wiringetctobefilled,andfirecaulkedwithappropriate materialsindrywallceilingtomaintainfirerating. Noted: o Onedesignatedexitfromlowerhallandfrontvestibuleisblockedbychairs(seeimage12). o Thereappearstobesufficientfireextinguishersthroughoutthebuilding. o Mechanicalroomappearsfireseparatedincludingdoor. o UpperHalldesignatedfor110personsonchairor75attables. Electrical Exitsignatuppersouthsidedoorishangingonwires(seeimage20). Warmingrackinbasementappearstobehomemade(seeimages22&23). B3 Page 75 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Exposedlumexwiringatseverallocations(vsarmoured) Wiringmarettesinmidairaboveblockedexit(seeimage25). RoofingInspections Noobservationstonoteatthistime. BarrierFreeInspections Wheelchairramplacksguardsandhandrails(seeimage6). Upperflooruniversalaccesswashroom&babychangestation(seeimage19) o GFIreceptaclenotednexttosink o ReceptacleonlightabovesinkisnotonaGFIcircuit. o Drainlineisnotprotected. o Providesignagetoindicatethatitisauniversalwashroom. Lowerflooruniversalaccesswashroom(seeimage21) o Drainlineisnotprotected. o Nosignagetoindicatethatitisauniversalwashroom. o Noramporelevatortoaccess. EnvironmentalAssessment Noobservationstonoteatthistime. Image 1: Front entrance door fine crack & deteriorating Image 2: South side windows cracks above, extending mortar into brickwork B4 Page 76 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 nd Image 3: South side 2 basement window Image 4: South face brickwork deteriorating and loose deteriorating sillbricks in various areas Image 5: Shed roof at south side draining onto brickwork Image 6: Wheelchair ramp below. Image 7: Vinyl cladding missing off of door frameImage 8: Eavestrough above south side B5 Page 77 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Image 9: Broken exhaust vent from basement washroomImage 10: Sump pump exhausting through a piece of downspout Image 11: Broken tree limbImage 12: Chairs piled in stairwell B6 Page 78 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Image 13: No fire separation between upper hall, lower Image 14: Missing downspouts at northeast corner & hall, and front vestibulemid-north corner of the roof Image 15: Draperies & stage curtains in main hallImage 16: Guard at inside south side stair Image 17: No railing at side stair to stageImage 18: Furnace room serving as messy storage area B7 Page 79 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Image 19: Universal washroom & baby change stationImage 20: Exit sign at upper south side door, hanging on wires Image 21: Lower floor universal access washroomImage 22: Homemade warming rack in basement Image 23: Homemade warming rack in basementImage 24: 4x4 unprotected secondary support posts in basement B8 Page 80 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Image 25: Wiring marettes in mid-air above blocked exit Image 26: Previous roof leak at southwest corner Image 27: Doors and frames to be replaced with 45 min fire rated steel frames and slab doors B9 Page 81 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 FBEZ!DPNNVOJUZ!IBMM Jnnfejbuf!Nfejvn!)2.Mpx!!Dpef!Sfgfsfodf! Efgjdjfodz!Tvhhftufe!Tpmvujpo! )1!Zst*!6!Zst*!)7.21!Zst*!)PCD* Sump pump is exhausting through a Add splash pad and grade away from $2003.1.18.1 piece of downspout next to the building, the building. ponding (see image 10). Broken tree limb behind building (see Cut back tree branches sufficient to not $500-Building maintenance image 11). Branches are in contact with contact roof. the asphalt roof shingles at the rear of the building and will damage the shingles. Fine diagonal crack and deteriorated Monitor, no immediate solution $2,500-Ongoing building mortar over front entrance door (see required. maintenance image 1). Cracks above all south side windows, some extending into brickwork (see image 2). South face brickwork has deteriorated mortar and loose bricks in various areas (see image 4). Fine cracks above all windows on the north side and west (front) are similar to south side condition. Broken exhaust vent from basement Replace exhaust vent.$506.2.2.1 washroom (see image 9). 9.32.3.2 nd South side 2 basement window from Replace sill. $3009.7.6.2 west: deteriorated sill needs work (see image 3). Door frame at top of ramp is missing vinyl Add vinyl cladding or replace the door $300 9.27.12 cladding (see image 7). frame. Shed roof at south side is draining onto Install kickout to protect brickwork.$509.26.18 brickwork below and should have a kickout (see image 5). There are no eavestroughs on the main Add eavestroughs and downspouts to $25009.26.18 roof. control water. Missing downspouts at northeast corner & Reinstall downspouts. $2009.26.18.2 mid-north corner of the roof (see image 14). Door to storage area under stage is off its Install hinges. $50-Building maintenance hinges. Main Lobby Non Compliance No Add fire rated doors and type X 5/8 $6,5003.2.1.4 fire separations between upper hall, lower drywall. Install Exit Signs above doors. hall and entrance vestibule (see image Penetrations fire caulked. 13). Wall finish in main hall Replace Lauan wood paneling in main $8,000 hall with fire resistant drywall, taped and sealed. Rear Stairwell Non Compliance for fire Replace door with 45 min FR door and $16003.4.4.1 (1) rating, and non compliant railings (image frame; Add appropriate hardware. 16) Replace existing railing to code, and add missing railing on stairs One designated exit from lower hall and Remove chairs. No cost.3.4.4.4 (6) front vestibule is blocked by chairs (see image 12). Draperies in main hall may not have Check if they have the appropriate No cost.3.1.13.2 required flame spread (see image 15). ratings. B10 Page 82 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Guard at inside of south side stair is 30 Replace railing. $1,5003.4.6.6 (2) tall with 5 spaces between pickets (see 3.4.6.6 (5) image 16). No railing at side of stairs to the stage Add railing. $2003.4.6.5 (see image 17). 4x4 unprotected secondary support posts Add 5/8 Type X drywall to clad $1,900 3.1.7.5 in basement (see image 24).Basement columns. Basement ceiling openings ceiling openings in rated ceiling. require to be filled in with drywall (large opening), insulation and fire caulk. Homemade warming rack in basement, Homemade warming rack to be $1,000 for OESC 02-100 may not be certified. reviewed by local ESA inspector inspection through an electrical contractor, or remove and replace with a CSA warming rack. Exit sign at upper south side door is Repair exit sign. $1003.4.5.1 hanging on wires (see image 20). Wiring marettes in mid-air above blocked Identify and secure wiring and marettes $100OESC 4-008 exit (see image 25). as required to joists. Wheelchair ramp lacks guards and Previous report also noted structural $20,0003.8.3.4 handrails (see image 6). deficiencies, remove and replace ramp. Receptacle on light above sink is not Ensure receptacle is not operable, or $500OESC 26-700 (11) likely on a GFI circuit. install a GFI breaker at panel. Upper floor universal washroom - drain Protect drain line. $1503.8.3.11 (1) d line is not protected. Upper floor universal washroom - no Order and install sign.$1003.8.3.1 signage to indicate that it is a universal washroom. Lower floor universal washroom - drain Protect drain line. $1503.8.3.11 (1) d line is not protected. Lower floor universal washroom no Order and install sign.$1003.8.3.1 signage to indicate that it is a universal washroom. Lower floor universal washroom no Further engineering design.$7,5003.8.3.4 ramp or elevator to access. TOTAL ESTIMATED COSTS: $450$7,100$0 B11 Page 83 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 ReferencePhotoAppendix Pic # 1 Pic # 2 Pic # 3Pic # 4 Pic # 5Pic # 6 B12 Page 84 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Pic # 7Pic # 8 Pic # 9Pic # 10 B13 Page 85 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Pic # 11Pic # 12 Pic # 13Pic # 14 B14 Page 86 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Pic # 15Pic # 16 Pic # 17Pic # 18 B15 Page 87 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Pic # 19Pic # 20 Pic # 21Pic # 22 Pic # 23Pic # 24 B16 Page 88 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEadyCommunityHall,OroMedonte,ON PROJECTNo.160200 Pic # 25 Pic # 26 B17 Page 89 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 APPENDIX C 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 90 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessment.EadyCommunityHall,OroMedonte,ON PROJECTNo.160200 EdgarCommunityHall OroMedonte,Ontario BuildingConditionAssessment PROJECTNo:160200 126MISSISSAGASTREETEAST,ORILLIA,ON,L3V1V7 PH.7053255400FX.7053258400 WWW.STEENHOFBUILDING.COM 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 91 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEdgarCommunityHall,OroMedonte,ON PROJECTNo.160200 OBSERVATIONS OntheafternoonofMonday,June13,2016,Mr.JerrySlavish,MAATO&DougHackbart,P.Eng.of SteenhofBuildingServicesGroupassessedtheEdgarCommunityHall. SiteWork Noobservationstoreportatthistime. ExteriorWalls&Structure Cracksnotedinexteriorplaster,bothonfoundationandwallsectionabove.Someextendfrom foundationtoroof(seeimages1&2). Atthefrontentranceextension,thehorizontalwoodsidingisprojectingbeyondthetrimboard andthejunctionisnotsealed(seeimage3). Therewasabreakintheeavestroughonthesideofthebuildingfacingtheparkinglot(see image5). Thereisadamageddownspoutabovethefrontentranceaddition(seeimage6). Thefrontentranceadditionisnotproperlysealedtothemainstructureinseveralareas(see image4). Theexteriorbasementstairaccessfoundationisindistress.Theblockwallsareshiftedand bowingonthesidewithgapsupto3/4_.Alsothebaseslabisseverelycracked.Firstimpression issueduetotheopenexteriorside(seeimage7). isfrostheave Windows&ExteriorDoors Stonewindowsillsarecracked,deterioratedandpatchingmaterialisfailing(seeimage8). Thefrontdoorhasonlyadeadboltanddoorcloser;thereisnounlockedlatchingprovided(see image9). Roofing&InteriorWork Servicematerialsandequipmentinthefrontlobbyshouldbemovedtoasecurelocation(see image13). Mechanical,&Plumbing Openingsaroundmechanicalandelectricalpenetrationsfromthemechanicalroomhavenot beenfiresealed(seeimage11). Thecombustionairductforthewaterheaterhasbeenpluggedwithapieceofinsulation(see image12). Mechanicalroomiscurrentlylitteredwithdebrisetc.thatshouldberemoved(seeimage10). FirePrevention,Security&LifeSafetySystems Noncompliantfireseparationorfiredoorsbetweenthefrontentrancelobbyandthebasement ormainhallrooms(seeimage14). C2 Page 92 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEdgarCommunityHall,OroMedonte,ON PROJECTNo.160200 o Codereference9.2.3.15.(1)and3.4.4.1.(1)OBCstatesthatexitstairsshallbeseparated bya1hourfireseparation. o Thedoorfromthelobbytothemainhallandthedoortothebasementfromthelobby shallbereplacedwith45minutedoorsandhardware,associatedrepairs. o Thewallsseparatingthelobbyfromthemainhallandbasementdonotappeartobe separatedbya1hourfireseparation.A5/8_firerateddrywallshallbeinstalled,sealed andtapedtoprovidethefireseparation.Removalofwainscotingisrecommendedfor easeofinstallation,whereapplicable. Noncompliantrailings o Interiorrailingswithinthefacilityarenoncompliantormissing;thoseexistingdonot extend12_paststairsateachend. NonCompliantDraperyandwallfinishes o Referencetocodes2.3.2.1.(1),9.2.2.4.(1),3.1.4.5.(3),subsection3.1.11(OBC)andNFPA 705toDraperyandfinishesflamespread. o Draperyinmainhalldonotcarryflamespreadrating,shallberemoved/replaced o InteriorwallfinishesconsistofLauanplywoodpaneling,whichisinstalledabovethe woodplankpaneling(wainscoting).TheLauanplywoodisnotlabelledastotheflame spreadratingandisassumedtobenoncompliantandshallbecoveredbyfireresistant drywall.Thewainscotingconsistingofwoodplanksarecompliantanddonotrequire anymodification. Noncompliantfireseparations o Codereferences2.2.2.1(OFC)statesthatiffireseparationsbetweenrooms,corridors, shaftsandotherspacesaredamaged,toaffecttheintegrityoftheseparationtheyshall berepairedtoreinstatetheintegrityoftheseparation. o Allopenings,pipepenetrationsandincidentaldamageshallberepairedandsealedwith approvedmaterials.Ceilingsshallbepatchedwith5/8_firerateddrywallforlarger openingsandcutouts,pipepenetrationsshallbefirecaulkedaspermanufacturers_ instructions,anddamagefiretapedandsealedwhereapplicable.(seeimage#11) Noted:Thereisapipeprojectingfromthefloorclosetothewallofthefrontentrancethatcould presentatrippinghazardclosetothestair(seeimage15). Electrical Theelectricalconnectionmastabovethemeterisnotsecuredtothewall(seeimage17). AGFIreceptacleisrecommendedatthemainhallcoffeestation(seeimage16). RoofingInspections Noobservationstoreportatthistime. BarrierFreeInspections Thereisnodelineationoftherampbetweenslopedandflatsections,rampisnoncompliant (seeimage18). Therailingalongtherampwasnotsecureatsomelocations(seeimage19). C3 Page 93 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEdgarCommunityHall,OroMedonte,ON PROJECTNo.160200 Theredidnotappeartobesufficientroomaroundtherailingtogripit. Someofthepicketspacingsontheguardalongsidetherampweregreaterthan100mm. Washroomhasmostoftherequirementsforuniversalaccessexceptthefollowing(seeimage 20): o Drainlineundersinkisnotprotected. o Spaceforwheelchairnexttotoiletisnotavailable. Elevator/StairConditionInspections Noobservationstoreportatthistime. EnvironmentalAssessment Noobservationstoreportatthistime. Image 1: Cracks in exterior plaster (foundation)Image 2: Cracks in exterior plaster (wall) Image 3: Front entrance extension - horizontal Image 4: Front entrance addition is not properly wood siding seal to the main structure C4 Page 94 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEdgarCommunityHall,OroMedonte,ON PROJECTNo.160200 Image 5: Break in eavestrough on side of building Image 6: Damaged downspout facing the parking lot Image 7: Severely cracked base slab at exterior Image 8: Cracked stone window sills basement stair access Image 9: Front door only has a deadbolt and door Image 10: Service materials and equipment in the closerfront lobby C5 Page 95 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEdgarCommunityHall,OroMedonte,ON PROJECTNo.160200 Image 11: Openings around mechanical & Image 12: Combustion air duct for the water electrical penetrations in mechanical roomheater plugged with a piece of insulation Image 13: Mechanical room littered with debrisImage 14: No fire separation or fire doors between the front entrance lobby and the basement or main hall rooms Image 15: Pipe projecting from the floor close to Image 16: GFI receptacle is recommended at the the wall of the front entrancemain hall coffee station C6 Page 96 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEdgarCommunityHall,OroMedonte,ON PROJECTNo.160200 Image 17: Electrical connection mast above the Image 18: No delineation of the ramp between meter not secured to the wallsloped and flat sections Image 19: Railing on ramp is not secure at some Image 20: Washroom locations, some members exhibit wood rotting C7 Page 97 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEdgarCommunityHall,OroMedonte,ON PROJECTNo.160200 FEBSDPNNVOJUZIBMM Jnnfejbuf!NfejvnMpxDpef!Sfgfsfodf! Efgjdjfodz!Tvhhftufe!Tpmvujpo! )1!Zst*!)2.6!Zst*!)7.21!Zst*!)PCD*! Cracks in exterior plaster, both on Rout and seal cracks to prevent $3009.20.3 foundation and wall section above. rain penetration.9.20.4 Some extend from foundation to roof (see images 1 & 2). At the front entrance extension, the Ensure siding is secure. Add $8009.27.2 horizontal wood siding is projecting thicker corner piece if required and 9.27.4.1 beyond the trim board and the caulk horizontal siding to vertical 9.27.6.3 junction is not sealed (see image 3). trims and gaps. Break in the eavestrough on the side Repair eavestrough, if possible or $500 (for -Building of the building facing the parking lot replace if necessary.both)maintenance (see image 5). Damaged downspout above the front entrance addition Replace damaged downspout. (see image 6). The front entrance addition is not Repair with sealant.$2005.6.2.1 properly sealed to the main structure in several areas (see image 4). The exterior basement stair access Replace block wall and slab. Add $10,000 - -Building foundation is in distress. The block exterior door to reduce frost. $15,000maintenance walls are shifted and bowing on the Insulating the entrance would also side with gaps up to 3/4. Also the help. base slab is severely cracked. First impression is frost heave issue due to the open exterior side (see image 7). Stone window sills are cracked; Replace window sills. $3,000-Building deteriorated & patching material is maintenance failing (see image 8). The front door has only a deadbolt Install new hardware. $1,0003.1.8.13 and door closer; there is no unlocked latching provided (see image 9). Openings around mechanical and Seal all openings with drywall, tape $2003.1.9 electrical penetrations from the and seal (larger openings), fire 2.2.2.1 (OFC) mechanical room have not been fire caulk as per manufacturers sealed (see image 11). instructions. The combustion air duct for the water Remove insulation from air duct. No cost. heater has been plugged with a piece of insulation (see image 12). Non-compliant Entrance Lobby: there Add 5/8 fire rated drywall to each $10,0003.2.1.4 is no fire separation or fire rated side of existing wall floor to ceiling doors between the front entrance and replace door with fire rated lobby and the basement or main hall door c/w exit device. rooms (see image 14). C8 Page 98 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... BuildingConditionAssessmentEdgarCommunityHall,OroMedonte,ON PROJECTNo.160200 Interior railings do not extend 12 Extend rails at each end. $1,2003.4.6.5 (10) past each end of the last step in the exit stairs. Non-compliant wall finish in the main Replace Lauan wood paneling with $7500 hall, non-fire resistant material (wood fire resistance drywall, taped and wainscot is acceptable) sealed. Seal all penetrations as necessary. There is a pipe projecting from the Cut off pipe so it is flush with floor. $503.8.1.3 floor close to the wall of the front entrance that could present a tripping hazard close to the stair (see image 5). The electrical connection mast above Secure electrical mast to the wall. $500OESC Section 28 the meter is not secured to the wall (see image 17). A GFI receptacle is recommended at Install GFI receptacle. $250OESC - 26-700 (11) the main hall coffee station (see image 16). There is no delineation of the ramp Add delineation strips to ramp as $1,5003.8.3.18 between sloped and flat sections (see per code. image 18). 3.8.3.4 (1) e, vi Secure and replace posts as The railing along the ramp was not necessary.3.8.3.4 (1) e, v secure at some locations (see image 19). Install handrail that is easy to grip 3.8.3.4 (1) e. i and spaced from guard for ease. There did not appear to be sufficient room around the railing to grip it. Adjust pickets or add as necessary. Some of the picket spacings on the guard alongside the ramp were greater than 100mm. Washroom drain line under sink is not Redesign and make washroom $20,0003.8.3.11 (1) d protected and space for wheelchair compliant to code. next to toilet is not available. TOTAL ESTIMATED COSTS:$41,950$17,000$0 C9 Page 99 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 APPENDIX D 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 100 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment . _Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 Hawkestone Community Hall Oro-Medonte, Ontario Building Condition Assessment PROJECT No: 160200 126 MISSISSAGA STREET EAST, ORILLIA, ON, L3V 1V7 PH. 705-325-5400 FX. 705-325-8400 WWW.STEENHOFBUILDING.COM 126 MISSISSAGA ST. E, ORILLIA, ON L3V 1V7 WWW.STEENHOFBUILDING.COM P. 705.325.5400 October 25, 2016 Page 101 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 OBSERVATIONS On the afternoon of Monday, June 20, 2016, Mr. Doug Hackbart, P.Eng. of Steenhof Building Services Group assessed the Hawkestone Community Hall. Site Work Front step bottom riser is 9 ½_ vs 6_ risers on remaining risers (see image 1). Exterior railings have all been extended 12_ past the edge of the stairs on the front stairs and ramp (see image 2). On the left side of the front entrance stairs, there is a broken corner to the blockwork below the landing (see image 3). Exterior Walls & Structure There are wooden headers over existing basement windows and windows which have been filled in and covered with cement parging; it is separating and falling off to re-expose the wood in a number of locations (see image 4). The exterior stucco has a few cracks; rear left corner, over window right side, front right corner. Some sealant smeared over has not repaired the issue (see image 5). Windows & Exterior Doors On the right side, there are 3 upper level windows which have wood trims projecting to the stucco surface; the surface and perimeter of these trims do not appear to be well sealed (see image 6). The basement exit door connects to 3 steps up to it from the basement floor (see image 7). Roofing & Interior Work Maintenance personnel advised that the upper hall hardwood floor has been sanded to its limit and will need to be replaced the next time it requires refinishing. There are two pieces of wainscot vertical strips broken off at the chair rail by the second window on the right in the main hall (see image 24). Mechanical & Plumbing The building appears to be on a well with a water purification and storage system in the basement. It appears that sewage is pumped to the septic field. The bird screen over the exhaust from the barrier- free washroom is broken (see image 8). There is a brick chimney over the furnace area which has had some brick repair, it does not have an obvious cap with drip edge and is no longer in use (see image 9). Intake and outlet pipes to the high efficiency furnace are not sealed at the outside wall (able to see light coming through). These pipes are also not sealed at the water service room wall or the furnace room wall, which appears to be intended as a fire separation (see image 10). There is an 8_ duct from the exterior to the furnace room, which was the fresh air intake for the previous furnace, and is now stuffed with insulation at the mechanical room. It is not sealed or D2 Page 102 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 dampered at the wall and interferes with a new door frame installed in this room (see image 11). There is an oil tank from the previous furnace which is no longer used and should be removed from the basement. Oil line also noted, flattened in mechanical room. The ceiling diffuser at the basement exit door is not secured to the ceiling (see image 12). There is a portable dehumidifier in the middle of the basement connected to a floor drain (see image 13). There is currently a gas line that has been run to the electric water heater; likely for conversion at end of service (see image 14). Fire Prevention, Security & Life Safety Systems Non-compliant fire separation or fire doors between the front entrance lobby and the basement or main hall rooms (see image 14). o Code reference 9.2.3.15.(1) and 3.4.4.1.(1) OBC states that exit stairs shall be separated by a 1 hour fire separation. (see image 15). o The door from the lobby to the main hall and the door to the basement from the lobby shall be replaced with 45 minute doors and hardware, associated repairs. o The walls separating the lobby from the main hall and basement do not appear to be separated by a 1 hour fire separation. A 5/8_ fire rated drywall shall be installed, sealed and taped to provide the fire separation. Removal of wainscoting is recommended for ease of installation, where applicable. o Devices to hold open doors shall be removed. Non-compliant fire separations o Code references 2.2.2.1 (OFC) states that if fire separations between rooms, corridors, shafts and other spaces are damaged, to affect the integrity of the separation- they shall be repaired to reinstate the integrity of the separation. o All openings, pipe penetrations and incidental damage shall be repaired and sealed with approved materials. Ceilings shall be patched with 5/8_ fire rated drywall for larger openings and cutouts, pipe penetrations shall be fire caulked as per manufacturers_ instructions, and damage fire taped and sealed where applicable. (see image 19 &20) o Areas noted for repairs include (but not limited to): o electrical room to kitchen; o furnace room to kitchen; o back storage room (see images 19 & 20) ; o room with hot water tanks; o mechanical room to back kitchen(nette) o room containing HRV o doors to service rooms to be rated (45 min) (image 17) Non-compliant stairs to basement level o Stairs to basement are non-compliant, risers are not uniform and railings do not extend past stairs (image 16 & 25) Non-compliant exit signage o Missing exit sign(s) at main door D3 Page 103 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 o Non-functioning exit light packs in basement; recommended to check all periodically Non-compliant smoke/heat detectors o Missing in storage and service rooms, to be installed o Lobby detector missing (base left on post) Non-compliant fire rating on support o There appears to be wood columns supporting wood beams in the basement which are not fire protected (see image 18). Fire extinguishers are installed at all exit doors and at the kitchen and mechanical rooms. Remainder of Exit signs and emergency lighting appear to be installed at the appropriate locations. All smoke detectors appear to be stand-alone battery operated where installed. There is a defibrillator on site in the front lobby. The basement ceiling tiles are not likely rated as a fire-resistant. Other open areas appear to be drywalled with ceiling tiles affixed. To ensure main room in basement is compliant, recommended to remove a ceiling tile to visual confirm same construction. If no drywall is present, the ceiling is non- compliant and requires drywall installed to maintain fire separation. Electrical The exterior conduit leading to the AC unit at the rear of the building is separated at the rear corner, exposing the conductors (see image 21). The electrical service has been upgraded to a 64 slot breaker panel and is connected to a variety of romex and armoured cables (see image 22). There is a light in front of the water service room which is not secured to the electrical box above it. Roofing Inspections The steel roof appeared to be in good condition with no obvious deficiencies noted. Barrier-Free Inspections There is a universal access ramp leading to the front door which appears to be in good condition The door operator & pads appear to operate correctly but has to be turned off for the door to be locked. The handicap washroom does not have the prescribed distance beside the toilet, the plumbing under the sink is not protected, the mirror is too high and there is no coat hook. It has a reasonable size floor area, has the grab bars and the leaver faucets. It is not strictly to Code but it still fairly functional (see image 23). Environmental Assessment No observations to be noted at this time. D4 Page 104 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 1: Front step Image 2: Exterior railing Image 3: Broken corner to the blockwork below the Image 4: Cement parging separating and falling off landing. to expose the wood Image 5: Cracks in the exterior stucco (rear left Image 6: Right side of building: surface and corner, over window right side, front corner) perimeter of the trims on the 3 windows do not appear to be well sealed. D5 Page 105 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 7: 3 steps connecting off of the basement exit Image 8: Bird screen over the exhaust from the door barrier-free washroom Image 9: Brick chimney Image 10: Intake & outlet pipes not sealed for fire separation Image 11: 8_ duct from the exterior to the furnace Image 12: Ceiling diffuser at the basement exit door room, requires sealing D6 Page 106 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 13: Portable dehumidifier in the middle of the Image 14: Electric water heater basement Image 15: All doors to the front lobby from both Image 16: Railing on stairs to the basement levels are not in fire separation and do not latch Image 17: 3 hollow metal doors to the furnace room Image 18: Wood columns supporting wood beams in the basement D7 Page 107 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 19: 8_ duct in the rear right basement storage Image 20: 8_ duct in the rear right basement storage room requiring repair & sealing room Image 21: Exterior conduit leading to the AC unit at Image 22: 64 slot breaker panel the rear of the building is separated at the rear corner Image 23: Handicap washroom Image 24: Two pieces of wainscot vertical strips are nd broken off at the chair rail by the 2 window on right D8 Page 108 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 25: Non-compliant stair (riser) D9 Page 109 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 HAWKESTONE COMMUNITY HALL Immediate Medium Low Code Reference Deficiency Suggested Solution (0 Yrs) (1-5 Yrs) (6-10 Yrs) (OBC) Front step bottom riser is 9 ½ vs 6 Regrade gravel to provide 6 rise. $5003.4.6.8 (5) risers on remaining risers (see image 1). On the left side of the front entrance Requires maintenance work such as $1,500- Building stairs, there is a broken corner to mortar repair and patching. maintenance the blockwork below the landing (see image 3). There are wooden headers over Chip off loose parging and replace $1,000- Building existing basement windows and parging as necessary. maintenance windows which have been filled in and covered with cement parging; it is separating and falling off to re- expose the wood in a number of locations (see image 4). The exterior stucco has a few Monitor cracks. No cost. - Building cracks; rear left corner, over maintenance window right side, front right corner. Some sealant smeared over has not repaired the issue (see image 5). On the right side, there are 3 upper Exposed wood to be cleaned and $1,200- Building level windows which have wood painted with good quality exterior maintenance trims projecting to the stucco grade paint. surface; the surface and perimeter of these trims do not appear to be well sealed (see image 6). The basement exit door connects to Railing required on one side of $7503.4.6.5 3 steps up to it from the basement egress stair. floor (see image 7). Hardwood floor has been sanded to Replace when time to be refinished. $1,500- Building its limit and will need to be replaced maintenance the next time it requires refinishing. There are two pieces of wainscot Replace wainscot. $500- Building vertical strips broken off at the chair maintenance rail by the second window on the right in the main hall (see image 24). The bird screen over the exhaust Replace broken screen. $50- Building from the barrier- free washroom is maintenance broken (see image 8). There is a brick chimney over the Recommend lowering to below roof $500- Building furnace area which has had some when it begins to deteriorate and maintenance brick repair, it does not have an roof over. obvious cap with drip edge and is no longer in use (see image 9). D10 Page 110 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 Intake and outlet pipes to the high Seal pipes at exterior wall surface. $2505.6.2.1 efficiency furnace are not sealed at 6.2.4.13 the outside wall (able to see light coming through). The intake and outlet pipes are also Fire stop all penetrations through $5003.1.9 not sealed at the water service fire separation surrounding furnace. room wall or the furnace room wall, Remove any pipes and ducts that which appears to be intended as a are no longer required. fire separation (see image 10). There is an 8 duct from the exterior to the furnace room, which was the fresh air intake for the previous furnace, and is now stuffed with insulation at the mechanical room. It is not sealed or dampered at the wall and interferes with a new door frame installed in this room (see image 11). All doors to the front lobby from Reconfigure and reconstruct the $5,0003.2.1.4 both levels are not in fire seperation assemblies. Further engineering and do not latch; they all have fold-required. down hold-open devices as well (see image 15). Railings on stairs to the basement Extend railings where possible (not $1,5003.4.6.5 (10) do not extend to the bottom of the interfering with doors, etc.) stairway (let alone 12 past) and stop flush with the stairs at the top as well (see image 16). The wall from the entrance lobby to Further engineering required. $2,0003.2.1.4 the upper and lower halls does not appear to be designed as a fire separation. There appears to be wood columns Clad assemblies with fire rated $1,2003.1.7.5 supporting wood beams in the drywall to be installed. basement which are not fire protected (see image 18). The basement ceiling tiles are not All basement structure to be fire $3,0003.2.1.4 likely rated as a fire-resistant. rated 1hr to floor above. Replace with fire rated ceiling. In the rear right basement storage Access locked room and determine $5,000To be determined. room, the drywall ceiling has been purpose of duct required to specify cut out and the joists cut off to requirement. install an 8 duct from a locked room adjacent. The duct is not sealed at the wall and the storage room does not have a smoke detector. The door is Masonite (see images 19 & 20). D11 Page 111 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Hawkestone Community Hall, Oro-Medonte, ON PROJECT No. 160200 The exterior conduit leading to the Reconnect exterior conduit. $50- Building AC unit at the rear of the building is maintenance separated at the rear corner, OESC 12-918 exposing the conductors (see image 21). There is a light in front of the water Repair light fixture. $150- Building service room which is not secured maintenance to the electrical box above it. OESC 02-112 The handicap washroom does not Handicap washroom should be $15,0003.8.3.12 have the prescribed distance beside redesigned and renovated to the toilet, the plumbing under the conform to code. sink is not protected, the mirror is too high and there is no coat hook. It has a reasonable size floor area, has the grab bars and the leaver faucets. It is not strictly to Code but it still fairly functional (see image 23). TOTAL ESTIMATED COSTS:$40,150 $1,000 $0 D12 Page 112 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... TOWNSHIPOFOROMEDONTE,BUILDINGASSESSMENT PROJECTNo.160200 APPENDIX E 126MISSISSAGAST.E,ORILLIA,ONL3V1V7WWW.STEENHOFBUILDING.COMP.705.325.5400October25,2016 Page 113 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment . __Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 Jarratt Community Hall Oro-Medonte, Ontario Building Condition Assessment PROJECT No: 160200 126 MISSISSAGA STREET EAST, ORILLIA, ON, L3V 1V7 PH. 705-325-5400 FX. 705-325-8400 WWW.STEENHOFBUILDING.COM 126 MISSISSAGA ST. E, ORILLIA, ON L3V 1V7 WWW.STEENHOFBUILDING.COM P. 705.325.5400 October 25, 2016 Page 114 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 OBSERVATIONS On the afternoon of Friday, July 8, 2016, Mr. Doug Hackbart, P.Eng. of Steenhof Building Services Group assessed the Jarratt Community Hall. Site Work Pavestone walk at front from the road to the entrance door. The parking lot is gravel. Exterior Walls & Structure The building has been clad with vinyl siding and has an aluminum soffit and fascia, in good condition (see image 33). Damproofing of foundation is evident at grade. Windows & Exterior Doors Front door: Vertical rod exit devices and closures installed on both exit doors (see image 1). All windows appear to have been replaced with vinyl frames and sealed units. Interior Work One of the store rooms (right off front entrance opening) into the upper hall was padlocked and therefore not inspected. Upper hall floor is very worn and simple plywood at washroom end (see image 12). Lower Hall o Kitchen cabinets are older, formica countertops (see image 27) Two electric stoves and one glass door refrigerator Three sinks plus hand wash sink o Rear right of lower hall _ another storage room (see image 31) Location of second sump pump is below exit stairs from upper hall Hollow metal door & frame c/w closure and latching but no label noted Room is drywalled and taped Mechanical, & Plumbing Mechanical room (basement) o Large door with steel cladding on both faces and a flat plate latching, not rated, no closure, not operable from inside (see image 21) o Oil furnace, oil tank (see image 23) o Access panel for furnace not installed (see image 22) o Electric water heater o Bracket for fire extinguisher, but no extinguisher o 8 x 8 louvered opening in wall for combustion air (see image 24) E2 Page 115 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 o Being used for storage o No cover on sump (see image 25) o Water system c/w 2 filters and UV system noted; pump and tank not located (see image 32). Fire Prevention, Security & Life Safety Systems Exit sign, emergency light, fire extinguisher & fire safety plan noted at front door. Wall from lobby to basement appears to be fire rated; c/w fire rated doors and exit devices at both basement doors _ left door is binding and failed to self-latch by closure only (see image 14). Rails to basement are extended beyond nosings at top and bottom, older flat plate type 2_ wide x ¼_ thick steel. Non-compliant - Double doors to the upper hall have closures but are not latching and shall have panic hardware installed (see image 3). Non-compliant - stairs to the upper hall have railings 28_ above nosings and pickets 6_ c/c. Exits signs, emergency lights and fire extinguishers noted at all upper hall exits (see image 4). All upper hall exits have exit devices (see image 5). There are no smoke detectors in the washrooms. Storage room at front, left of main hall (see image 9) o No light o No smoke detector o Wood door o Damaged floor vent (see image 10) Defibrillator mounted in upper hall. Non-compliant - Corridor and stairs to supply storage closet at rear of upper hall (see image 13) to code reference 9.2.3.15 (1). o Corridor is open on both sides, above the washrooms, main hall exit, lower hall exit requires fire separation and protection (see images 2 & 17) o Stairs are non-compliant, treads too high o Railings are non-compliant Store room is dry-walled and taped (see image 16) Door is hollow metal in pressed steel frame with latching & closure but is not labeled. No smoke detector Exit signs are no longer functioning (light packs) and should have battery replaced. Other exit signs shall be tested periodically. Non-Compliant Drapery and wall finishes o Reference to codes 2.3.2.1.(1), 9.2.2.4.(1), 3.1.4.5.(3), subsection 3.1.11 (OBC) and NFPA 705 to Drapery and finishes flame spread. o Drapery in main hall do not carry flame spread rating, shall be removed/replaced Basement storage left of entrance (see image 15) o Walls and ceiling drywalled and taped o Door is hollow metal in pressed steel frame with latching & closure but is not labeled. E3 Page 116 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 o Interior foundation wall has a significant crack (see image 18). o No smoke detector o Water egress was noted on day of visit Crawlspace to right of entrance o Raised access panel c/w plywood door from lower hall (see image 19). o Heated space c/w light o No drywall to walls or ceiling (see image 20) Basement columns are 4_ diameter steel pipes, not fire rated (see image 29). One uncovered drywall opening noted at a previous light fixture location (see image 30). Electrical Smoke detectors in the main hall do not appear to be properly located (see image 11). Lower Hall - All wiring in conduit or armored cable were exposed Electrical panel found inside kitchen upper cabinet o Appears older but not fully utilized (see image 28) One smoke detector noted in lower hall There is an area light about mid-point of the ramp Roofing Inspections Asphalt roof shingles are in very poor condition on south & west sides _ needs immediate replacement (see image 34) Barrier-Free Inspections Men_s and women_s washrooms are both upstairs to the main hall (see images 6 & 7) o They have sufficient size and layout for universal access o Grab bars are both installed horizontally o Drains under sinks are not protected & faucets do not have lever handles (see image 8) The universal access ramp has a 3_ steps at the ramp to landing junction (see image 26) There is no door actuator or pads at the door into the hall. Environmental Assessment No observations to report at this time. E4 Page 117 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 1: Front door _ vertical rod exit devices and Image 2: Exit stairwell wall not drywalled on closures installed on both doors backside Image 3: Double doors to upper hall Image 4: Exit signs, emergency lights & fire extinguishers Image 5: Upper hall exits Image 6: Men_s washroom E5 Page 118 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 7: Women_s washroom Image 8: Drains under signs Image 9: Storage room at front, left of main hall Image 10: Damaged floor vent Image 11: Smoke detectors in the main hall Image 12: Upper hall floor, very worn E6 Page 119 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 13: Corridor and stairs to supply storage Image 14: No fire protection of structure closet, rear of upper hall Image 15: No fire protection of structure Image 16: Store room is drywalled and taped E7 Page 120 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 17: Basement storage left of entrance Image 18: Crack in interior foundation wall Image 19: Crawlspace to right of entrance - raised Image 20: Crawlspace to right of entrance - no access panel with plywood door from lower hall drywall to walls or ceiling Image 21: Mechanical room - Large door with steel Image 22: Access panel for furnace, not installed cladding on both faces E8 Page 121 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 23: Oil furnace, oil tank Image 24: 8 x 8 louvered opening in wall Image 25: No cover on sump Image 26: Universal access ramp has a 3_ step at the ramp to landing junction Image 27: Kitchen Image 28: Electrical panel inside kitchen upper cabinet E9 Page 122 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 Image 29: Basement columns are 4_ diameter steel Image 30: Uncovered drywall opening from pipes previous light fixture location Image 31: Storage room, located rear right of lower Image 32: Water system and UV system hall Image 33: Vinyl siding, aluminum soffit and fascia Image 34: Asphalt roof shingles E10 Page 123 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 JARRATT COMMUNITY HALL Immediate Medium Low Code Reference Deficiency Suggested Solution (0 Yrs) (1-5 Yrs) (6-10 Yrs) (OBC) Upper hall floor is very worn and Replace when time to be refinished. $2,500- Building simple plywood at washroom end maintenance (see image 12). Mechanical room - large door with This door should be replaced with a $2,5003.1.8.4 (2) steel cladding on both faces and a proper fire rated door. 3.1.8.11 flat plate latching, not rated, no 3.1.8.13 closure, not operable from inside (see image 21). Mechanical room - access panel for Reinstall panel for furnace. $50- Building furnace not installed (see image 22). maintenance Mechanical room - bracket for fire Replace fire extinguisher. $1003.2.5.17 extinguisher, but no extinguisher. Mechanical room no cover on Install cover on sump. $50- Building sump (see image 25). maintenance Wall from lobby to basement Adjust door to prevent binding. $1503.1.8.13 appears to be fire rated; c/w fire rated doors & exit devices at both basement doors left door is binding and failed to self-latch by closure only (see image 14). Rails to basement are extended Recommend replacing rails as they $1,5003.4.6.5 beyond nosings at top and bottom, are difficult to grip. All handrails to older flat plate type 2 wide x ¼ meet requirements with OBC. thick steel. The stairs to the upper hall have Guard and pickets need to be $7503.4.6.6 railings 28 above nosings and replaced with code compliant pickets 6 c/c. options. There are no smoke detectors in the Install smoke detectors. $2503.2.4.12 washrooms. Storage room at front, left of main Replace floor vent. $100- Building hall has a damaged floor vent (see maintenance image 10). Storage room at front, left of main Install smoke detector. $2503.2.4.12 hall does not have a smoke detector. No fire protection is provided to Extend rated walls on both sides to $5003.1.7.5 corridor below (6 x 7). ceiling and above at time of washroom modification. At the corridor and stairs to supply If room is used for janitorial supply $5003.3.1.20 (1) storage closet at rear of upper hall -storage, then it requires a 1hr rating; door is hollow metal in pressed steel replace door and frame with labelled frame with latching and closure but option. is not labeled. Basement storage left of entrance - Not currently leaking, continue to - Building interior foundation wall has a monitor.maintenance significant crack (see image 18). Basement storage left of entrance Install smoke detector. $2503.2.4.12 has no smoke detector. Crawlspace to the right of the Add 5/8 drywall to ceiling and $1,0003.1.7.5 entrance _ has no drywall to walls exterior wall face and fire stop is 3.1.9 E11 Page 124 of 260 12.c) Report No. OCS2017-01, Shawn Binns, Director, Operatio... Building Condition Assessment Jarratt Community Hall, Oro-Medonte, ON PROJECT No. 160200 or ceiling.required. Basement columns are 4 diameter Fire rate support columns with 5/8 $2,5003.1.7.5 steel pipes, not fire rated (see image drywall enclosure. 29). One uncovered drywall opening Cap opening. $503.1.9 noted at a previous light fixture - Building location (see image 30). maintenance Smoke detectors in the main hall do Add or relocate smoke detectors as $2503.2.4.12 not appear to be properly located. required. Asphalt roof shingles are in very Replace roof. $12,0009.26 poor condition on south & west sides (see image 34). Mens and womens washrooms are There is sufficient room to renovate $30,0003.8.3.12 both upstairs to the main hall (see one or both washrooms to meet the 3.8.3.11 (1) d images 6 & 7). They have sufficient universal accessibility standards, but size and layout for universal access. it would reduce the number of Drains under sinks are not protected washrooms. We recommend one & faucets do not have lever handles universal access washroom and (see image 8). either a single mens and a single womens or make all three unisex. The universal access ramp has a 3 Raise and anchor to ramp to $1,5003.8.3.4 steps at the ramp to landing junction eliminate stop. (see image 26). There is no door actuator or pads at Add to door at top of ramp. $2,5003.8.3.3 (6) the door into the hall. TOTAL ESTIMATED COSTS:$55,250 $4,000 $0 E12 Page 125 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 126 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 127 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 128 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 129 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 130 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 131 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 132 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 133 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 134 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 135 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 136 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 137 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 138 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 139 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 140 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 141 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 142 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 143 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 144 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 145 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 146 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 147 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 148 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 149 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 150 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 151 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 152 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 153 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 154 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 155 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 156 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 157 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 158 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 159 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 160 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 161 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 162 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 163 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 164 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 165 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 166 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 167 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 168 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 169 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 170 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 171 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 172 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 173 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 174 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 175 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 176 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 177 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 178 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 179 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 180 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 181 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 182 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 183 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 184 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 185 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 186 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 187 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 188 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 189 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 190 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 191 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 192 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 193 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 194 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 195 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 196 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 197 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 198 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 199 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 200 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 201 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 202 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 203 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 204 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 205 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 206 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 207 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 208 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 209 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 210 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 211 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 212 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 213 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 214 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 215 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 216 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 217 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 218 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 219 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 220 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 221 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 222 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 223 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 224 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 225 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 226 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 227 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 228 of 260 12.d) Robin Dunn, CAO and Senior Management Team re: 2017 Bu... Page 229 of 260 13.b) Mayor H.S. Hughes, correspondence dated January 10, 20... Page 230 of 260 13.b) Mayor H.S. Hughes, correspondence dated January 10, 20... Page 231 of 260 13.c) Mayor H.S. Hughes, correspondence dated December 13, 2... Page 232 of 260 13.c) Mayor H.S. Hughes, correspondence dated December 13, 2... Page 233 of 260 14.a) Announcements of Interest to the Public: Orillia & Are... Page 234 of 260 14.a) Announcements of Interest to the Public: Orillia & Are... Page 235 of 260 14.a) Announcements of Interest to the Public: Orillia & Are... Page 236 of 260 14.b) Correspondence received January 17, 2017 from Chris Ba... Page 237 of 260 14.b) Correspondence received January 17, 2017 from Chris Ba... Page 238 of 260 14.b) Correspondence received January 17, 2017 from Chris Ba... Page 239 of 260 15.a) Correspondence from Association of Municipalities of O... AMO AGM AND ANNUAL CONFERENCE AMO Annual Conference Asset Management Symposium 2017 CONFERENCE ANNOUNCEMENT Human Services Symposium Ottawa will be hosting a number of events in 2017 in celebration of Canada_s 150th, including the AMO AGM & Annual Conference. As their calendar books up, so do hotel rooms in Ottawa. In order to manage a potential run on Past Events hotel rooms, and ensure that our delegates were able to book rooms in Ottawa, AMO moved up the hotel booking date to Monday, October 3 at 10 am. QUICK LINKS Please read the guest room booking policy in full prior to making any bookings at either the primary hotel or any of the secondary hotels. Rates, distance from the venue and cancellation policies are outlined both in the policy and on the booking sites of the individual hotels. To help you plan your stay, note that the conference will be held at the Shaw Convention Centre and the Westin Hotel. it will run from Sunday, August 13 to Wednesday, August 16, with programming on Sunday generally starting after 2:00 pm, concluding on Wednesday before noon. Conference registration will be made available shortly. DOWNLOAD Guestroom Booking Policy 2016 CONFERENCE INFORMATIONFUTURE CONFERENCE 2017 Exhibitor Prospectus With over 1900 participants in attendance, the 2016 AMO AGM DATES and Annual Conference was a great success. If you are looking CONTACT _August 13 - 16, 2017 | Ottawa for: Navneet Dhaliwal _August 19 - 22, 2018 | Ottawa 1.Presentations and proceedings from the Conference click Special Events & Business _August 18 - 21, 2019 | Ottawa here. Development Coordinator _August 16 - 19, 2020 | Ottawa 2.Sponsor information click here. ndhaliwal@amo.on.ca 3.Exhibitor details click here. T 416.971.9856 ext. 330 TF 1.877.426.6527 F 416.971.6191 Related Sites| Programs| Connect| Contact Us| Newsroom| Accessibility| Privacy©2013-2017 Association of Municipalities of Ontario Page 240 of 260 15.b) Correspondence dated January 9, 2017 from Gayle Wood, ... Nottawasaga Valley Conservation Authority January 9, 2017 Mayor Harry Hughes & Council The Township of Oro-Medonte Via email: Doug Irwin, Town Clerk Dear Mayor Hughes & Council Re: NVCA 2017Municipal Levy On December 16, 2016the NVCA Board of Directors approved the circulated 2017 NVCA Budget. As you are aware, the NVCA circulated our Draft 2017Budget to our 18 member municipalities on October 3, 2016for a 30 day review and comment. The NVCA Board and staff look forward to implementing the 2017 Conservation Authority programs supported by the approved budget including: Private land stewardship, restoration and reforestation Conservation Authority education and recreation Flood forecasting and warning Municipal source water protection Natural Hazard and Natural Heritage protection in accordance with the Planning Actand Provincial Regulations Environmental monitoring and preparation of watershed report cards Implementing the NVCA 2015-2018 Strategic and Business Plans Climate Change. The approved budget will enable the NVCA, in partnership with our local Municipalities, and residents to continue to protect and restore the environment, reduce and or prevent flood and erosion hazards to property and persons, and continue to support the health of the local residents and the health of our local economy. The following table provides a comparison to the 2016 levy and identifies your portion of the municipal levy for 2017. 20162017$ Increase% Increase Total Levy$2,147,883.48$2,196,487.39$48,603.912.26% Oro Medonte$168,303.85$171,134.92$2,831.071.68% Nottawasaga Valley Conservation Authority th 8195 8Line, Utopia, ON L0M 1T0 T: 705-424-1479F: 705-424-2115 A member of Conservation Ontario Page 241 of 260 15.b) Correspondence dated January 9, 2017 from Gayle Wood, ... As well, the NVCA introduced the Asset Levy in support of the approved Asset Management Plan. This plan has a ten year forecast of our capital replacement costs and will ensure that the NVCA has the funds moving forward to adequately maintain our current assets. The amount required each year for the next ten years is $129,926.50 apportioned out the same way as the general levy. The NVCA has heard from our municipalities that many would like to phase this in over 4 years, so each municipality has the option to either go all in or phase it in. The financial impacts for your municipality are shown below. Please let us know which option your municipality would like to choose by the end of January. All InYear 1 Year 2 Year 3Year 4 & (2017)(2018)(2019)onward Oro Medonte$10,122.96$3,340.59$6,681.18$10,123.01$11,583.61 **Year 2 onward is an estimate based on the current value assessment An invoice for levy will be sent out late January or February. Should you have any questions regarding the approved NVCA budget or associated conservation programs please contact me directly. Thank you again for your ongoing support of the NVCA. I would like to also thank the NVCA Board Members for their continued governance, ensuring that the watershed conservation needs are best served. Sincerely, D. Gayle Wood, CMM3 Chief Administrative Officer Copy:NVCA Board Member,Councillor Phil Hall Municipal CAO,Robin Dunn Page 242 of 260 17.a) By-Law No. 2017-011: A By-law to Amend By-law 2016-063... Building Code Act, 1992, Page 243 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Municipal Act, 2001, S.O. 2001, c. 25, Municipal Act, 2001, Page 244 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 245 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 246 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 247 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 248 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 249 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 250 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 251 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 252 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 253 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 254 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 255 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 256 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 257 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 258 of 260 17.b) By-Law No. 2017-013: A By-law to Appoint a Meeting Inv... Page 259 of 260 19.a) By-Law No. 2017-010: Being a by-law to confirm the pro... Municipal Act, 2001, S.O. 2001, C. 25, as amended Page 260 of 260